D4Spec never uses language models to approximate engineering calculations. Every equation is executed by a deterministic solver, and the loads are checked against the reference houses and results of CSA F280-12 Annexes G, J and K.
Four deterministic modules: envelope heat transfer, foundations and air leakage, equipment capacity checks, and preliminary duct sizing.
Computes conductive and solar heat transfer for every room at any of the 679 Canadian weather stations of Clause 4, and adds the room loads into the building totals of Clauses 5.2.7 and 6.3.1.
Replaces crude below-grade rules of thumb and fixed air-change estimates with official Natural Resources Canada physical models.
Checks the heat pump or furnace you specify against the capacities Clauses 5.3 and 6.3 require.
Turns room-by-room loads into supply airflow targets and preliminary duct sizes on a provisional room layout, every assumption stated. Ducts go on a separate HVAC design sheet, not part of the CSA F280-12 permit.
Every engine change is run against the reference houses of Annexes G, J and K, and every release carries a digest of its source code. D4Spec has not yet been through Clause 8 verification.
Whole-house and room loads are run against Annexes J and K; BASESIMP below-grade losses and AIM-2 air leakage against NRCan's calculators and test cases.
Three Annex J heating cases for Archetype 3 reach 97.0–97.7 % of the reference, short of the 98 % of Clause 8.4.1. They are kept in the tests as known gaps until resolved.
Every run records its engine version and the revision it calculated; a permit prints only from the current engine.