Deterministic Physics Core · CAN/CSA-F280-12 (Update No. 3, R2025)

Loads by CSA F280-12. Zero LLM Math.

D4Spec never uses language models to approximate engineering calculations. Every equation is executed by a deterministic solver, and the loads are checked against the reference houses and results of CSA F280-12 Annexes G, J and K.

Clause-by-Clause Fidelity Across Every Canadian Climate Zone

Four deterministic modules: envelope heat transfer, foundations and air leakage, equipment capacity checks, and preliminary duct sizing.

01

Clauses 5 & 6 · Envelope & Fenestration Solver

Computes conductive and solar heat transfer for every room at any of the 679 Canadian weather stations of Clause 4, and adds the room loads into the building totals of Clauses 5.2.7 and 6.3.1.

  • Effective Thermal Resistance (RSI): Framing and rim joists counted through CSA F280-12 Tables 7A and 7B.
  • Opening Deduction & Sub-Assemblies: Automatic net opaque wall area deduction as windows and doors are assigned to exterior walls.
  • Orientation-Specific Solar Gain: Direction-resolved fenestration SHGC, overhangs, and interior shading factors (Table 4).
02

NRCan BASESIMP & AIM-2 Infiltration Physics

Replaces crude below-grade rules of thumb and fixed air-change estimates with official Natural Resources Canada physical models.

  • 145 BASESIMP Foundation Configurations: The NRCan BASESIMP correlations the standard's calculators use, over the soil's seasonal temperature (slab on grade, basement, crawl space, walk-out).
  • AIM-2 Air Leakage Solver: Combines blower-door airtightness (ACH50, and the ELA where measured) with wind-and-stack driving forces and shelter classes.
  • Mechanical Ventilation (Clauses 5.2.3.2, 5.2.3.3): Models HRV/ERV sensible heat recovery efficiency alongside unbalanced exhaust makeup air loads.
03

Equipment Capacity Checks (Clauses 5.3 and 6.3)

Checks the heat pump or furnace you specify against the capacities Clauses 5.3 and 6.3 require.

  • Specified Unit Check: Checks a heat pump, or a furnace with or without an air conditioner, against the building totals and each room's delivery; no permit prints for a unit that fails.
  • Heat Pump Balance Point: Finds the balance point from the unit's ratings and lockout temperature, and checks the unit with its backup heat against Clause 5.3.1.
  • Sensible & Latent Cooling: Internal occupant and appliance gains; latent load by Clause 6.3.1's multiplier, or direct per Annex B.
04

Preliminary Trunk-and-Branch Duct Sizing

Turns room-by-room loads into supply airflow targets and preliminary duct sizes on a provisional room layout, every assumption stated. Ducts go on a separate HVAC design sheet, not part of the CSA F280-12 permit.

  • Available Static Pressure (ASP) Budget: Deducts coil and filter drops, and stated allowances for registers, grille and damper, from the fan's external static pressure (ESP).
  • Total Effective Length (TEL) & Friction Rate: Sums straight duct runs and fitting equivalent lengths to determine the governing friction rate (in.w.c./100 ft).
  • Velocity Limits: Sizes rectangular trunks and round branches within velocity and aspect-ratio limits.

Run Against the Standard's Reference Houses

Every engine change is run against the reference houses of Annexes G, J and K, and every release carries a digest of its source code. D4Spec has not yet been through Clause 8 verification.

REFERENCE CASES

Case-by-Case Checks

Whole-house and room loads are run against Annexes J and K; BASESIMP below-grade losses and AIM-2 air leakage against NRCan's calculators and test cases.

OPEN ITEMS

Gaps Are Tracked, Not Hidden

Three Annex J heating cases for Archetype 3 reach 97.0–97.7 % of the reference, short of the 98 % of Clause 8.4.1. They are kept in the tests as known gaps until resolved.

REPRODUCIBILITY

Engine Version Records

Every run records its engine version and the revision it calculated; a permit prints only from the current engine.