D4Spec Workbench · Annex D Guided Workflow & Provenance

AI Assists the Takeoff. The Designer Signs the Permit.

D4Spec combines AI blueprint reading with a guided workbench ordered by the summary sheet of CSA F280-12 Annex D (Figure D.1)—giving designers speed without ever sacrificing engineering sign-off.

STAGE 01 · DRAWING INTAKE

AI Blueprint Reading

Reads PDF floor plans and schedules into typed candidate rooms, windows, and assemblies, each read listed by its file.

STAGE 02 · ANNEX D GUIDE

Clause-Referenced Explanation Cards

Plain-English questions tell the designer where to find each detail on drawings and how nominal vs. effective RSI convert.

STAGE 03 · PROVENANCE GATE

Zero Silent Defaults

Every value shows whether it was entered, read, signed, or taken from a file—and the permit waits until every read room is confirmed.

STAGE 04 · AHJ SUBMITTAL

Vector PDF Permit

Prints the CSA F280-12 permit for the designer to sign, with a SHA-256 digest of its data, and the B.C. single-zone cooling form where needed.

How D4Spec Protects Engineering Sign-Off

Built around a single source of truth: the permit prints the table of inputs Clause 7.1 asks for, with assumed values marked.

STRUCTURED BLUEPRINT EXTRACTION

Candidate Suggestions from the Drawings

When a designer uploads a residential drawing set, D4Spec uses a multimodal AI model's structured output to propose room dimensions, exterior wall orientations, and window/door schedules—never overwriting confirmed project data silently.

  • Marked Until Confirmed: Each read is listed by its file. Read rooms stay marked until confirmed; other values wait for the designer's signature.
  • Strict Schema Validation: Each read value must fit its field's type and range; a read that differs from the set's printed figures raises a ticket.
  • Fail-Closed Disambiguation: Missing or illegible drawing annotations are flagged explicitly for designer input rather than filled with hidden defaults.
ANNEX D GUIDED WORKBENCH

14 Chapters of Clause-Referenced Engineering Flashcards

Following the order of the CAN/CSA-F280-12 Annex D summary sheet (Figure D.1), D4Spec guides experienced designers and newcomers alike through every required building envelope and mechanical input.

  • Where to Find It on Drawings: Directs the user to the drawings that hold each value (e.g., wall sections, window schedule, or energy report).
  • Live Revision Delta: Displays the immediate heating (W) and cooling (W) impact of every parameter change against the previous revision.
  • Pre-Permit Completeness Gate: Lists every remaining unconfirmed input or open ticket before unlocking final PDF generation.

Inspect the Municipal Permit Package

The permit is three pages: the summary, the table of inputs, and the room results with the declaration, plus continuation and assembly worksheet pages where needed. Equipment, ducts and room airflow go on a separate HVAC design sheet, not part of the permit. Select a page to preview it; the values shown are from a sample project, for illustration only.

D4SPEC | CAN/CSA-F280-12 MUNICIPAL PERMIT SUBMITTAL

Page 1 of 3 — Summary: Required Capacities & Building Loads

SAMPLE · PREPARED WITH D4SPEC
Capacities Any System Shall Meet
Clauses 5.3 and 6.3
Total Building Heat Loss (Clause 5.2.7)
29,167 Btuh (8,548 W)
Total Summer Design Gain (Clause 6.3.1)
27,700 Btuh (2.31 Tons)
Attached Documents & Notes
As listed on Annex D, Figure D.1